1.
Data Brief ; 54: 110386, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38646196

ABSTRACT

Respiratory data was collected from 20 subjects, with an even sex distribution, in the low-risk clinical unit at the University of Canterbury. Ethical consent for this trial was granted by the University of Canterbury Human Research Ethics Committee (Ref: HREC 2023/30/LR-PS). Respiratory data were collected, for each subject, over three tests consisting of: 1) increasing set PEEP from a starting point of ZEEP using a CPAP machine; 2) test 1 repeated with two simulated apnoea's (breath holds) at each set PEEP; and 3) three forced expiratory manoeuvres at ZEEP. Data were collected using a custom pressure and flow sensor device, ECG, PPG, Garmin HRM Dual heartrate belt, and a Dräeger PulmoVista 500 Electrical Impedance Tomography (EIT) machine. Subject demographic data was also collected prior to the trial, in a questionnaire, with measurement equipment available. These data aim to inform the development of pulmonary mechanics models and titration algorithms.

2.
HardwareX ; 17: e00512, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38333423

ABSTRACT

Respiratory disease is a major contributor to healthcare costs, as well as increasing morbidity and early mortality. The device presented is used to simulate the effects of Chronic Obstructive Pulmonary Disease (COPD) in healthy people. The intended use is to provide data equivalent to COPD data measured from those who are ill for initial validation of respiratory mechanics models. It would thus eliminate the need to test unhealthy and/or fragile subjects, or the need for invasive or costly equipment based test methods. The device is used in conjunction with an open-access venturi-based flow sensor, to measure pressure, flow, and breath tidal volume. The device simulates the pressure and flow profiles of a person who has COPD including the non-linear increased resistance to end-exhalation and gas trapping. To achieve this non-linearity, a combination of high and low resistance outlets is used. Thus, the simulator allows the collection of patient-specific COPD-like breathing data in a non-invasive manner from healthy subjects. The device is low-cost with the majority of the parts 3D printed using a Prusa mini 3D printer and PLA filament.

3.
Comput Methods Programs Biomed ; 244: 107988, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38171168

ABSTRACT

BACKGROUND AND OBJECTIVE: Recruitment maneuvers with subsequent positive-end-expiratory-pressure (PEEP) have proven effective in recruiting lung volume and preventing alveoli collapse. However, determining a safe, effective, and patient-specific PEEP is not standardized, and this more optimal PEEP level evolves with patient condition, requiring personalised monitoring and care approaches to maintain optimal ventilation settings. METHODS: This research examines 3 physiologically relevant basis function sets (exponential, parabolic, cumulative) to enable better prediction of elastance evolution for a virtual patient or digital twin model of MV lung mechanics, including novel elements to model and predict distension elastance. Prediction accuracy and robustness are validated against recruitment maneuver data from 18 volume-controlled ventilation (VCV) patients at 7 different baseline PEEP levels (0 to 12 cmH2O) and 14 pressure-controlled ventilation (PCV) patients at 4 different baseline PEEP levels (6 to 12 cmH2O), yielding 623 and 294 prediction cases, respectively. Predictions were made up to 12 cmH2O of added PEEP ahead, covering 6 × 2 cmH2O PEEP steps. RESULTS: The 3 basis function sets yield median absolute peak inspiratory pressure (PIP) prediction error of 1.63 cmH2O for VCV patients, and median peak inspiratory volume (PIV) prediction error of 0.028 L for PCV patients. The exponential basis function set yields a better trade-off of overall performance across VCV and PCV prediction than parabolic and cumulative basis function sets from other studies. Comparing predicted and clinically measured distension prediction in VCV demonstrated consistent, robust high accuracy with R2 = 0.90-0.95. CONCLUSIONS: The results demonstrate recruitment mechanics are best captured by an exponential basis function across different mechanical ventilation modes, matching physiological expectations, and accurately capture, for the first time, distension mechanics to within 5-10 % accuracy. Enabling the risk of lung injury to be predicted before changing ventilator settings. The overall outcomes significantly extend and more fully validate this digital twin or virtual mechanical ventilation patient model.


Subject(s)
Lung , Respiratory Mechanics , Humans , Respiratory Mechanics/physiology , Respiration, Artificial/methods , Positive-Pressure Respiration/methods , Respiration
4.
Data Brief ; 52: 109903, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38161653

ABSTRACT

The breathing dataset presented is collected from 20 healthy individuals at the University of Canterbury using a device to simulate the pressure and flow profiles of obstructive pulmonary disease. Specifically, the expiratory non-linear resistance, which generates the characteristic expiratory pressure-flow loop lobe seen in obstructive disease. Ethical consent for the trial was granted by the University of Canterbury Human Research Ethics Committee (Ref: HREC 2022/26/LR). Data was collected using an open-source data collection device connected to a Fisher and Paykel Healthcare SleepStyle SPSCAA CPAP. The trial was conducted at CPAP PEEP levels of 4 and 8 cmH2O, as well as at ZEEP (0 cmH2O) with no CPAP attached. The simulation device was a modular device connected to the expiratory pathway, consisting of a free volume diversion and fixed high resistance outlet. Three simulation levels were selected for testing, achieved by changing the size of the elastic free volume. The intended use of this dataset is for the initial validation and development of respiratory pulmonary mechanics models, using data collected from healthy people with simulated disease prior to clinical testing.

5.
Data Brief ; 52: 109874, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38146285

ABSTRACT

Resting breathing data was collected from 80 smokers, vapers, asthmatics, and otherwise healthy people in the low-risk clinical unit at the University of Canterbury. Subjects were asked to breathe normally through a full-face mask connected to a Fisher and Paykel Healthcare SleepStyle SPSCAA CPAP device. PEEP (Positive End-Expiratory Pressure) support was increased from 4 to 12 cmH2O in 0.5 cmH2O increments. Data was also collected during resting breathing at ZEEP (0 cmH2O) before and after the PEEP trial. The trial was conducted under University of Canterbury Human Research Ethics Committee consent (Ref: HREC 2023/04/LR-PS). Data was collected by and Dräeger PulmoVista 500 EIT machine and a custom Venturi-based pressure and flow sensor device connected in series with the CPAP and full-face mask. The outlined dataset includes pressure, flow, volume, dynamic circumference (thoracic and abdominal, and cross-sectional aeration. Subject demographic data was self-reported using a questionnaire given prior to the trial.

6.
HardwareX ; 16: e00489, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38058767

ABSTRACT

Respiratory model-based methods require datasets containing enough dynamics to ensure model identifiability for development and validation. Rapid expiratory occlusion has been used to identify elastance and resistance within a single breath. Currently accepted practice for rapid expiratory occlusion involves a 100 ms occlusion of the expiratory pathway. This article presents a low-cost modular rapid shutter attachment to enable identification of passive respiratory mechanics. Shuttering faster than 100 ms creates rapid expiratory occlusion without the added dynamics of muscular response to shutter closure, by eliminating perceived expiratory blockage via high shutter speed. The shutter attachment fits onto a non-invasive venturi-based flow meter with separated inspiratory and expiratory pathways, established using one-way valves. Overall, these elements allow comprehensive collection of respiratory pressure and flow datasets with relatively very rapid expiratory occlusion.

7.
Sensors (Basel) ; 23(24)2023 Dec 12.
Article in English | MEDLINE | ID: mdl-38139620

ABSTRACT

(1) Background: Technically, a simple, inexpensive, and non-invasive method of ascertaining volume changes in thoracic and abdominal cavities are required to expedite the development and validation of pulmonary mechanics models. Clinically, this measure enables the real-time monitoring of muscular recruitment patterns and breathing effort. Thus, it has the potential, for example, to help differentiate between respiratory disease and dysfunctional breathing, which otherwise can present with similar symptoms such as breath rate. Current automatic methods of measuring chest expansion are invasive, intrusive, and/or difficult to conduct in conjunction with pulmonary function testing (spontaneous breathing pressure and flow measurements). (2) Methods: A tape measure and rotary encoder band system developed by the authors was used to directly measure changes in thoracic and abdominal circumferences without the calibration required for analogous strain-gauge-based or image processing solutions. (3) Results: Using scaling factors from the literature allowed for the conversion of thoracic and abdominal motion to lung volume, combining motion measurements correlated to flow-based measured tidal volume (normalised by subject weight) with R2 = 0.79 in data from 29 healthy adult subjects during panting, normal, and deep breathing at 0 cmH2O (ZEEP), 4 cmH2O, and 8 cmH2O PEEP (positive end-expiratory pressure). However, the correlation for individual subjects is substantially higher, indicating size and other physiological differences should be accounted for in scaling. The pattern of abdominal and chest expansion was captured, allowing for the analysis of muscular recruitment patterns over different breathing modes and the differentiation of active and passive modes. (4) Conclusions: The method and measuring device(s) enable the validation of patient-specific lung mechanics models and accurately elucidate diaphragmatic-driven volume changes due to intercostal/chest-wall muscular recruitment and elastic recoil.


Subject(s)
Respiratory Mechanics , Thoracic Wall , Adult , Humans , Respiratory Mechanics/physiology , Diaphragm/physiology , Lung/physiology , Abdomen
8.
Sci Data ; 10(1): 481, 2023 07 22.
Article in English | MEDLINE | ID: mdl-37481681

ABSTRACT

Continuous positive airway pressure (CPAP) ventilation is a commonly prescribed respiratory therapy providing positive end-expiratory pressure (PEEP) to assist breathing and prevent airway collapse. Setting PEEP is highly debated and it is thus primarily titrated based on symptoms of excessive or insufficient support. However, titration periods are clinician intensive and can result in barotrauma or under-oxygenation during the process. Developing model-based methods to more efficiently personalise CPAP therapy based on patient-specific response requires clinical data of lung/CPAP interactions. To this end, a trial was conducted to establish a dataset of healthy subjects lung/CPAP interaction. Pressure, flow, and tidal volume were recorded alongside secondary measures of dynamic chest and abdominal circumference, to better validate model outcomes and assess breathing modes, muscular recruitment, and effort. N = 30 subjects (15 male; 15 female) were included. Self-reported asthmatics and smokers/vapers were included, offering a preliminary assessment of any potential differences in response to CPAP from lung stiffness changes in these scenarios. Additional demographics associated with lung function (sex, age, height, and weight) were also recorded.


Subject(s)
Abdomen , Continuous Positive Airway Pressure , Respiratory Rate , Adult , Female , Humans , Male , Lung , Thorax
9.
Comput Biol Med ; 160: 106808, 2023 06.
Article in English | MEDLINE | ID: mdl-37163965

ABSTRACT

Hyperglycaemia is a common problem in neonatal intensive care units (NICUs). Achieving good control can result in better outcomes for patients. However, good control is difficult, where poor control and resulting hypoglycaemia reduces outcomes and confounds results. Clinically validated models can provide good control, and subcutaneous insulin delivery can provide more options for insulin therapy for clinicians. However, this combination has only been significantly utilised in adult outpatient diabetes, but could hold benefit for treating NICU infants. This research combines a well-validated NICU metabolic model with subcutaneous insulin kinetics models to assess the feasibility of a model-based approach. Clinical data from 12 very/extremely pre-mature infants was collected for an average study duration of 10.1 days. Blood glucose, interstitial and plasma insulin, as well as subcutaneous and local insulin were modelled, and patient-specific insulin sensitivity profiles were identified for each patient. Modelling error was low, where the cohort median [IQR] mean percentage error was 0.8 [0.3 3.4] %. For external validation, insulin sensitivity was compared to previous NICU cohorts using the same metabolic model, where overall levels of insulin sensitivity were similar. Overall, the combined system model accurately captured observed glucose and insulin dynamics, showing the potential for a model-based approach to glycaemic control using subcutaneous insulin in this cohort. The results justify further model validation and clinical trial research to explore a model-based protocol.


Subject(s)
Insulin Resistance , Intensive Care Units, Neonatal , Adult , Humans , Infant, Newborn , Blood Glucose/metabolism , Glycemic Control , Insulin
10.
Comput Biol Med ; 152: 106430, 2023 01.
Article in English | MEDLINE | ID: mdl-36543001

ABSTRACT

BACKGROUND: Current methods to diagnose and monitor COPD employ spirometry as the gold standard to identify lung function reduction with reduced forced expiratory volume (FEV1)/vital capacity (VC) ratio. Current methods utilise linear assumptions regarding airway resistance, where nonlinear resistance modelling may provide rapid insight into patient specific condition and disease progression. This study examines model-based expiratory resistance in healthy lungs and those with progressively more severe COPD. METHODS: Healthy and COPD pressure (P)[cmH2O] and flow (Q)[L/s] data is obtained from the literature, and 5 intermediate levels of COPD and responses are created to simulate COPD progression and assess model-based metric resolution. Linear and nonlinear single compartment models are used to identify changes in inspiratory (R1,insp) and linear (R1,exp)/nonlinear (R2Φ) expiratory resistance with disease severity and over the course of expiration. RESULTS: R1,insp increases from 2.1 to 7.3 cmH2O/L/s, R1,exp increases from 2.4 to 10.0 cmH2O/L/s with COPD severity. Nonlinear R2Φ increases (mean R2Φ: 2.5 cmH2O/L/s (healthy) to 24.4 cmH2O/L/s (COPD)), with increasing end-expiratory nonlinearity as COPD severity increases. CONCLUSION: Expiratory resistance is increasingly highly nonlinear with COPD severity. These results show a simple, nonlinear model can capture fundamental COPD dynamics and progression from regular breathing data, and such an approach may be useful for patient-specific diagnosis and monitoring.


Subject(s)
Pulmonary Disease, Chronic Obstructive , Humans , Pulmonary Disease, Chronic Obstructive/diagnosis , Lung , Airway Resistance/physiology , Forced Expiratory Volume , Exhalation
11.
J Diabetes Sci Technol ; 17(4): 1016-1028, 2023 Jul.
Article in English | MEDLINE | ID: mdl-35343255

ABSTRACT

OBJECTIVE: Accurate, safe glycemic management requires reliable delivery of insulin doses. Insulin can be delivered subcutaneously for action over a longer period of time. Needle-free jet injectors provide subcutaneous (SC) delivery without requiring needle use, but the volume of insulin absorbed varies due to losses associated with the delivery method. This study employs model-based methods to determine the expected proportion of active insulin present from a needle-free SC dose. METHODS: Insulin, C-peptide, and glucose assay data from a frequently sampled insulin-modified oral glucose tolerance test trial with 2U SC insulin delivery, paired with a well-validated metabolic model, predict metabolic outcomes for N = 7 healthy adults. Subject-specific nonlinear hepatic clearance profiles are modeled over time using third-order basis splines with knots located at assay times. Hepatic clearance profiles are constrained within a physiological rate of change, and relative to plasma glucose profiles. Insulin loss proportions yielding optimal insulin predictions are then identified, quantifying delivery losses. RESULTS: Optimal parameter identification suggests losses of up to 22% of the nominal 2U SC dose. The degree of loss varies between subjects and between trials on the same subject. Insulin fit accuracy improves where loss greater than 5% is identified, relative to where delivery loss is not modeled. CONCLUSIONS: Modeling shows needle-free SC jet injection of a nominal dose of insulin does not necessarily provide metabolic action equivalent to total dose, and this availability significantly varies between trials. By quantifying and accounting for variability of jet injection insulin doses, better glycemic management outcomes using SC jet injection may be achieved.


Subject(s)
Insulin, Regular, Human , Insulin , Adult , Humans , Injections, Jet , Injections, Subcutaneous , Glucose Tolerance Test
12.
J Clin Monit Comput ; 37(2): 389-398, 2023 04.
Article in English | MEDLINE | ID: mdl-35920951

ABSTRACT

Clinical measurements offer bedside monitoring aiming to minimise unintended over-distension, but have limitations and cannot be predicted for changes in mechanical ventilation (MV) settings and are only available in certain MV modes. This study introduces a non-invasive, real-time over-distension measurement, which is robust, predictable, and more intuitive than current methods. The proposed over-distension measurement, denoted as OD, is compared with the clinically proven stress index (SI). Correlation is analysed via R2 and Spearman rs. The OD safe range corresponding to the unit-less SI safe range (0.95-1.05) is calibrated by sensitivity and specificity test. Validation is fulfilled with 19 acute respiratory distress syndrome (ARDS) patients data (196 cases), including assessment across ARDS severity. Overall correlation between OD and SI yielded R2 = 0.76 and Spearman rs = 0.89. Correlation is higher considering only moderate and severe ARDS patients. Calibration of OD to SI yields a safe range defined: 0 ≤ OD ≤ 0.8 cmH2O. The proposed OD offers an efficient, general, real-time measurement of patient-specific lung mechanics, which is more intuitive and robust than SI. OD eliminates the limitations of SI in MV mode and its less intuitive lung status value. Finally, OD can be accurately predicted for new ventilator settings via its foundation in a validated predictive personalized lung mechanics model. Therefore, OD offers potential clinical value over current clinical methods.


Subject(s)
Positive-Pressure Respiration , Respiratory Distress Syndrome , Humans , Positive-Pressure Respiration/methods , Respiration, Artificial/methods , Lung , Respiratory Distress Syndrome/therapy , Ventilators, Mechanical , Respiratory Mechanics
13.
BMC Res Notes ; 15(1): 257, 2022 Jul 16.
Article in English | MEDLINE | ID: mdl-35842701

ABSTRACT

OBJECTIVES: A unique dataset of airway flow/pressure from healthy subjects on Continuous Positive Airway Pressure (CPAP) ventilation was collected. This data can be used to develop or validate models of pulmonary mechanics, and/or to develop methods to identify patient-specific parameters which cannot be measured non-invasively, during CPAP therapy. These models and values, particularly if available breath-to-breath in real-time, could assist clinicians in the prescription or optimisation of CPAP therapy, including optimising PEEP settings. DATA DESCRIPTION: Data was obtained from 30 subjects for model-based identification of patient-specific lung mechanics using a specially designed venturi sensor system comprising an array of differential and gauge pressure sensors. Relevant medical information was collected using a questionnaire, including: sex; age; weight; height; smoking history; and history of asthma. Subjects were tasked with breathing at five different rates (including passive), matched to an online pacing sound and video, at two different levels of PEEP (4 and 7 cmH2O) for between 50 and 180 s. Each data set comprises ~ 17 breaths of data, including rest periods between breathing rates and CPAP levels.


Subject(s)
Continuous Positive Airway Pressure , Respiration , Adult , Humans , Respiratory Rate
14.
Comput Biol Med ; 142: 105225, 2022 03.
Article in English | MEDLINE | ID: mdl-35032739

ABSTRACT

BACKGROUND: The intrinsic (muscular) patient effort driving inspiration in non-invasive ventilation modes, such as continuous positive airway pressure (CPAP) therapy, has not been identified from non-invasive data. Current CPAP settings are based on clinical judgment and assessment of symptoms of respiratory distress. Non-optimal settings, including too much positive end expiratory pressure (PEEP) can cause unintended lung injury and ventilator unloading, where patient effort drops and the CPAP device enables too much work being imposed on the injured lung. Currently, there is no non-invasive means of quantifying or identifying these effects. METHODS: A novel model-based method of ascertaining intrinsic patient work of breathing (WOB) in CPAP is developed based on linear single compartment and 2nd order b-spline models previously used in invasive ventilation modes. Results are compared to current clinical indications, such as total Imposed WOB from the CPAP device and beak length, the latter of which is the clinical metric used to indicate alveolar overdistension. Intrinsic and Imposed WOB are compared. The hypothesis is that ventilator unloading can be assessed as a decrease in Intrinsic WOB relative to Imposed WOB, as PEEP and associated ventilator unloading rise. This hypothesis is tested using 14 subjects from a CPAP trial of several breathing rates at two PEEP levels. RESULTS: The ratio of Intrinsic to Imposed WOB, normalised per unit tidal volume, decreased with increasing PEEP (4-7 cm H2O), capturing the expected trend of ventilator unloading. Ventilator unloading was observed across all breathing rates. Beak length measurements showed no conclusive evidence of capturing overdistension at higher PEEP or ventilator unloading. CONCLUSIONS: Patient Intrinsic WOB in CPAP was non-invasively quantified using model-based methods, based on pressure and flow measurements. The ratio of Intrinsic to Imposed WOB per unit tidal volume clearly and consistently showed ventilator unloading across all patients and breathing rates, with Intrinsic WOB decreasing with increasing PEEP. This trend was not observed in the current clinical metric of beak length. Non-invasively quantifying Intrinsic WOB and ventilator unloading is the critical first step to objectively optimising clinical CPAP settings, patient care, and outcomes.


Subject(s)
Continuous Positive Airway Pressure , Work of Breathing , Animals , Humans , Respiration, Artificial , Tidal Volume , Ventilators, Mechanical
15.
J Diabetes Sci Technol ; 16(5): 1208-1219, 2022 09.
Article in English | MEDLINE | ID: mdl-34078114

ABSTRACT

BACKGROUND: Critically ill ICU patients frequently experience acute insulin resistance and increased endogenous glucose production, manifesting as stress-induced hyperglycemia and hyperinsulinemia. STAR (Stochastic TARgeted) is a glycemic control protocol, which directly manages inter- and intra- patient variability using model-based insulin sensitivity (SI). The model behind STAR assumes a population constant for endogenous glucose production (EGP), which is not otherwise identifiable. OBJECTIVE: This study analyses the effect of estimating EGP for ICU patients with very low SI (severe insulin resistance) and its impact on identified, model-based insulin sensitivity identification, modeling accuracy, and model-based glycemic clinical control. METHODS: Using clinical data from 717 STAR patients in 3 independent cohorts (Hungary, New Zealand, and Malaysia), insulin sensitivity, time of insulin resistance, and EGP values are analyzed. A method is presented to estimate EGP in the presence of non-physiologically low SI. Performance is assessed via model accuracy. RESULTS: Results show 22%-62% of patients experience 1+ episodes of severe insulin resistance, representing 0.87%-9.00% of hours. Episodes primarily occur in the first 24 h, matching clinical expectations. The Malaysian cohort is most affected. In this subset of hours, constant model-based EGP values can bias identified SI and increase blood glucose (BG) fitting error. Using the EGP estimation method presented in these constrained hours significantly reduced BG fitting errors. CONCLUSIONS: Patients early in ICU stay may have significantly increased EGP. Increasing modeled EGP in model-based glycemic control can improve control accuracy in these hours. The results provide new insight into the frequency and level of significantly increased EGP in critical illness.


Subject(s)
Hyperglycemia , Insulin Resistance , Blood Glucose/analysis , Critical Care/methods , Critical Illness , Glucose , Humans , Insulin , Intensive Care Units
16.
J Diabetes Sci Technol ; 16(3): 732-741, 2022 05.
Article in English | MEDLINE | ID: mdl-33588609

ABSTRACT

BACKGROUND: The ability to measure insulin secretion from pancreatic beta cells and monitor glucose-insulin physiology is vital to current health needs. C-peptide has been used successfully as a surrogate for plasma insulin concentration. Quantifying the expected variability of modelled insulin secretion will improve confidence in model estimates. METHODS: Forty-three healthy adult males of Maori or Pacific peoples ancestry living in New Zealand participated in an frequently sampled, intravenous glucose tolerance test (FS-IVGTT) with an average age of 29 years and a BMI of 33 kg/m2. A 2-compartment model framework and standardized kinetic parameters were used to estimate endogenous pancreatic insulin secretion from plasma C-peptide measurements. Monte Carlo analysis (N = 10 000) was then used to independently vary parameters within ±2 standard deviations of the mean of each variable and the 5th and 95th percentiles determined the bounds of the expected range of insulin secretion. Cumulative distribution functions (CDFs) were calculated for each subject for area under the curve (AUC) total, AUC Phase 1, and AUC Phase 2. Normalizing each AUC by the participant's median value over all N = 10 000 iterations quantifies the expected model-based variability in AUC. RESULTS: Larger variation is found in subjects with a BMI > 30 kg/m2, where the interquartile range is 34.3% compared to subjects with a BMI ≤ 30 kg/m2 where the interquartile range is 24.7%. CONCLUSIONS: Use of C-peptide measurements using a 2-compartment model and standardized kinetic parameters, one can expect ~±15% variation in modelled insulin secretion estimates. The variation should be considered when applying this insulin secretion estimation method to clinical diagnostic thresholds and interpretation of model-based analyses such as insulin sensitivity.


Subject(s)
Diabetes Mellitus, Type 2 , Insulin Resistance , Adult , Blood Glucose/analysis , C-Peptide , Glucose Tolerance Test , Humans , Insulin , Insulin Secretion , Male
17.
J Diabetes Sci Technol ; 16(4): 945-954, 2022 07.
Article in English | MEDLINE | ID: mdl-33478257

ABSTRACT

OBJECTIVE: Model-based metabolic tests require accurate identification of subject-specific parameters from measured assays. Insulin assays are used to identify insulin kinetics parameters, such as general and first-pass hepatic clearances. This study assesses the impact of intravenous insulin boluses on parameter identification precision. METHOD: Insulin and C-peptide data from two intravenous glucose tolerance test (IVGTT) trials of healthy adults (N = 10 × 2; denoted A and B), with (A) and without (B) insulin modification, were used to identify insulin kinetics parameters using a grid search. Monte Carlo analysis (N = 1000) quantifies variation in simulation error for insulin assay errors of 5%. A region of parameter values around the optimum was identified whose errors are within variation due to assay error. A smaller optimal region indicates more precise practical identifiability. Trial results were compared to assess identifiability and precision. RESULTS: Trial B, without insulin modification, has optimal parameter regions 4.7 times larger on average than Trial A, with 1-U insulin bolus modification. Ranges of optimal parameter values between trials A and B increase from 0.04 to 0.12 min-1 for hepatic clearance and from 0.07 to 0.14 for first-pass clearance on average. Trial B's optimal values frequently lie outside physiological ranges, further indicating lack of distinct identifiability. CONCLUSIONS: A small 1-U insulin bolus improves identification of hepatic clearance parameters by providing a smaller region of optimal parameter values. Adding an insulin bolus in metabolic tests can significantly improve identifiability and outcome test precision. Assay errors necessitate insulin modification in clinical tests to ensure identifiability and precision.


Subject(s)
Insulin , Models, Biological , Adult , C-Peptide , Computer Simulation , Glucose Tolerance Test , Humans , Insulin/metabolism , Kinetics
18.
Comput Biol Med ; 141: 105022, 2022 02.
Article in English | MEDLINE | ID: mdl-34801244

ABSTRACT

BACKGROUND AND OBJECTIVE: Recruitment maneuvers (RMs) with subsequent positive-end-expiratory-pressure (PEEP) have proven effective in recruiting lung volume and preventing alveolar collapse. However, a suboptimal PEEP could induce undesired injury in lungs by insufficient or excessive breath support. Thus, a predictive model for patient response under PEEP changes could improve clinical care and lower risks. METHODS: This research adds novel elements to a virtual patient model to identify and predict patient-specific lung distension to optimise and personalise care. Model validity and accuracy are validated using data from 18 volume-controlled ventilation (VCV) patients at 7 different baseline PEEP levels (0-12cmH2O), yielding 623 prediction cases. Predictions were made up to ΔPEEP = 12cmH2O ahead covering 6x2cmH2O PEEP steps. RESULTS: Using the proposed lung distension model, 90% of absolute peak inspiratory pressure (PIP) prediction errors compared to clinical measurement are within 3.95cmH2O, compared with 4.76cmH2O without this distension term. Comparing model-predicted and clinically measured distension had high correlation increasing to R2 = 0.93-0.95 if maximum ΔPEEP ≤ 6cmH2O. Predicted dynamic functional residual capacity (Vfrc) changes as PEEP rises yield 0.013L median prediction error for both prediction groups and overall R2 of 0.84. CONCLUSIONS: Overall results demonstrate nonlinear distension mechanics are accurately captured in virtual lung mechanics patients for mechanical ventilation, for the first time. This result can minimise the risk of lung injury by predicting its potential occurrence of distension before changing ventilator settings. The overall outcomes significantly extend and more fully validate this virtual mechanical ventilation patient model.


Subject(s)
Lung , Models, Biological , Positive-Pressure Respiration , Respiratory Mechanics , Humans , Positive-Pressure Respiration/methods , Pressure , Respiratory Mechanics/physiology
19.
Comput Methods Programs Biomed ; 208: 106300, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34348200

ABSTRACT

BACKGROUND: Optimisation of mechanical ventilation (MV) and weaning requires insight into underlying patient breathing effort. Current identifiable models effectively describe lung mechanics, such as elastance (E) and resistance (R) at the bedside in sedated patients, but are less effective when spontaneous breathing is present. This research derives and regularises a single compartment model to identify patient-specific inspiratory effort. METHODS: Constrained second-order b-spline basis functions (knot width 0.05 s) are used to describe negative inspiratory drive (Pp, cmH2O) as a function of time. Breath-breath Pp are identified with single E and R values over inspiration and expiration from n = 20 breaths for N = 22 patients on NAVA ventilation. Pp is compared to measured electrical activity of the diaphragm (Eadi) and published results. RESULTS: Average per-patient root-mean-squared model fit error was (median [interquartile range, IQR]) 0.9 [0.6-1.3] cmH2O, and average per-patient median Pp was -3.9 [-4.5- -3.0] cmH2O, with range -7.9 - -1.9 cmH2O. Per-patient E and R were 16.4 [13.6-21.8] cmH2O/L and 9.2 [6.4-13.1] cmH2O.s/L, respectively. Most patients showed an inspiratory volume threshold beyond which Pp started to return to baseline, and Pp at peak Eadi (end-inspiration) was often strongly correlated with peak Eadi (R2=0.25-0.86). Similarly, average transpulmonary pressure was consistent breath-breath in most patients, despite differences in peak Eadi and thus peak airway pressure. CONCLUSIONS: The model-based inspiratory effort aligns with electrical muscle activity and published studies showing neuro-muscular decoupling as a function of pressure and/or volume. Consistency in coupling/dynamics were patient-specific. Quantification of patient and ventilator work of breathing contributions may aid optimisation of MV modes and weaning.


Subject(s)
Diaphragm , Respiration, Artificial , Humans , Lung
20.
Diabetologia ; 64(12): 2779-2789, 2021 12.
Article in English | MEDLINE | ID: mdl-34417843

ABSTRACT

AIMS/HYPOTHESIS: The minor A allele of rs373863828 (CREBRF p.Arg457Gln) is associated with increased BMI, but reduced risk of type 2 and gestational diabetes in Polynesian (Pacific peoples and Aotearoa New Zealand Maori) populations. This study investigates the effect of the A allele on insulin release and sensitivity in overweight/obese men without diabetes. METHODS: A mixed meal tolerance test was completed by 172 men (56 with the A allele) of Maori or Pacific ancestry, and 44 (24 with the A allele) had a frequently sampled IVGTT and hyperinsulinaemic-euglycaemic clamp. Mixed linear models with covariates age, ancestry and BMI were used to analyse the association between the A allele of rs373863828 and markers of insulin release and blood glucose regulation. RESULTS: The A allele of rs373863828 is associated with a greater increase in plasma insulin 30 min following a meal challenge without affecting the elevation in plasma glucose or incretins glucagon-like polypeptide-1 or gastric inhibitory polypeptide. Consistent with this point, following an i.v. infusion of a glucose bolus, participants with an A allele had higher early (p < 0.05 at 2 and 4 min) plasma insulin and C-peptide concentrations for a similar elevation in blood glucose as those homozygous for the major (G) allele. Despite increased plasma insulin, rs373863828 genotype was not associated with a significant difference (p > 0.05) in insulin sensitivity index or glucose disposal during hyperinsulinaemic-euglycaemic clamp. CONCLUSIONS/INTERPRETATION: rs373863828-A allele associates with increased glucose-stimulated insulin release without affecting insulin sensitivity, suggesting that CREBRF p.Arg457Gln may increase insulin release to reduce the risk of type 2 diabetes.


Subject(s)
Diabetes Mellitus, Type 2 , Insulin , Alleles , Blood Glucose , Diabetes Mellitus, Type 2/genetics , Humans , Insulin/genetics , Male , Native Hawaiian or Other Pacific Islander , Tumor Suppressor Proteins/genetics